EasyManuals Logo

Dynamatic EC 2000 User Manual

Dynamatic EC 2000
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
25
14. SPEED FILTER AVER
Allows for taking an average of the speed feedback readings. This is primarily used for non-
standard speed feedback configurations, noise affected configurations, or heavy loads not
getting up to speed in a timely manner (Default: 0).
15. SPEED FILTER CLAMP
Limits the amount of speed feedback readings done by the EC 2000. This is primarily used for
non-standard speed feedback configurations, noise affected configurations, or heavy loads
not getting up to speed in a timely manner (Default: 0).
16. MEMORY RESET EN
Allows the user to reset the stored parameters back to the factory defaults upon powering
or resetting the device (pressing the SW1 button on the 15-1200-1 logic board).
YES
NO (default)
Note: Parameters can also be reset back to factory defaults by placing a jumper between
terminals 32 and 29 on TB2, while also removing all other connections on TB2.
17. REVERSE SETPOINT
Allows the user to use a setpoint reference signal in reverse. For example, if a potentiometer
normally gives a full voltage signal to give a maximum speed reference, enabling this
parameter would tell the control to give a minimum speed reference with a full voltage signal
from that potentiometer.
ENABLE
DISABLE (default)
18. REVERSE CONTROL
Sometimes used in centrifuge applications, this allows the user to control the drive to go
“down” instead of “up.”
ENABLE
DISABLE (default)