Troubleshooting Guide 23
Flash
Code
Fault source
Sub-
code
Meaning & Remedy
3
4
Motor 1
Motor 2
00
Short circuit
Check the motor cables for damage
Motor brushes may be too stiff, bouncing against the case
o Replace motor brushes or motor
01
Open circuit
Check if the motor cables are loose
Motor brushes may be worn
o Turn wheels to reconnect
o Replace motor brushes or motor
02
Motor terminal connected to battery negative (-)
Check if the motor has been connected correctly
Check the motor cables for damage
03
Motor terminal connected to battery positive (+)
Check if the motor has been connected correctly
Check the motor cables for damage
04
Motor voltage not consistent during drive
Possible motor short circuit
o check the motor cables for damage
o Motor brushes may be too stiff and bouncing
Otherwise internal controller fault, contact Dynamic Controls
06
Intermittent short circuit
Check for damaged cables
Motor brushes may be too stiff, bouncing against the case
o Replace motor brushes or motor
All
other
Internal fault
Contact Dynamic Controls
M1
M2