Messages and Alerts
SkyView SE Pilot’s User Guide - Revision I 9-9
Spoken Alert
(if configured)
Message Displayed in
Message Window
SkyView sent a command to move
the trim motor but did not receive
feedback that the motor is
moving, or a trim switch was held
ON continuously for more than 5
seconds while Auto-Trim was
enabled.
System has switched to SkyView
Backup Battery.
A previously connected backup
battery is no longer detected or
has failed.
A full backup battery test was
performed, and it failed. See the
SkyView System Installation
Manual for further
troubleshooting information.
The display's internal temperature
is high. To prevent permanent
damage, the display may shut
down at any time unless
immediate action is taken to cool
it down.
EMS configuration files in SkyView
display units do not match.
The system has detected a wiring
fault in the LEVEL button.
The connected FLARM traffic
receiver has not replied to a
status query in the last 3 seconds.
The G meter is in the yellow
caution range.
The identified GPS position source
has failed. SkyView has switched
to the next available GPS position
source.
The Remote Magnetometer
module has failed or is not
communicating with SkyView.
Heading information is
unavailable.
Knob Control Panel is not
communicating with SkyView.