Messages and Alerts
SkyView SE Pilot’s User Guide - Revision I 9-9
Spoken Alert
(if configured)
Message Displayed in
Message Window
Visual Alert
(severity)
Description
"Caution"
AP TRIM MALFUNCTION
SkyView sent a command to move
the trim motor but did not receive
feedback that the motor is
moving, or a trim switch was held
ON continuously for more than 5
seconds while Auto-Trim was
enabled.
"Caution"
BACKUP BATTERY IN
USE
System has switched to SkyView
Backup Battery.
"Caution"
BACKUP BATTERY
UNAVAIL
A previously connected backup
battery is no longer detected or
has failed.
"Caution"
BATTERY TEST FAILED
A full backup battery test was
performed, and it failed. See the
SkyView System Installation
Manual for further
troubleshooting information.
"Caution"
CPU TEMP CRITICAL
The display's internal temperature
is high. To prevent permanent
damage, the display may shut
down at any time unless
immediate action is taken to cool
it down.
"Caution"
EMS SFG FILE
MISMATCH
EMS configuration files in SkyView
display units do not match.
"Caution"
EXT LEVEL BUTTON
STUCK
The system has detected a wiring
fault in the LEVEL button.
"Caution"
FLARM OFFLINE
The connected FLARM traffic
receiver has not replied to a
status query in the last 3 seconds.
"Gees" (repeats)
None
G-Meter is
displayed.
The G meter is in the yellow
caution range.
"Caution"
GPS # FAIL
The identified GPS position source
has failed. SkyView has switched
to the next available GPS position
source.
"Caution"
HDG SOURCE FAIL
The Remote Magnetometer
module has failed or is not
communicating with SkyView.
Heading information is
unavailable.
"Caution"
KNOB PANEL OFFLINE
Knob Control Panel is not
communicating with SkyView.