9
Diamond Board
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFF—ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
ACTIVE
OVERLOAD
OPENING
LIGHT HEAVY
ERD STATUS
GATE STATUS
Eagle Diamond Control Board
Rev A4
TIMER
MIN
MASTER
SLAVE
MAX
1
ON
2 3 4 5 6 7 8
M/S PHASE
01
CLOSING
SELECT
OPEN
LIMIT
OPENING CLOSING CLOSE
LIMIT
CLOSE
STOP
OPEN
SLAVE MASTER
+ – + –
#14#13
+ MAGLOCK
- 24 VDC
#10
+ ALARM
- 12 VDC
#11
MAGLOCK
RELAY
#9
POWER
24 VAC
#12
REVERSE
LOOP
#2
PHANTOM
LOOP
#3
EXIT
OPEN
#4
KEY
KEYPAD
#6
EDGE
SENSOR
#8
STOP
#5
CLOSE
#7
GND
GND
RCVR
24VAC
#1
LOOP WIRE INPUT
EXIT
OPEN
SHADOW
LOOP
REVERSE
LOOP
COMM PORTOUTPUTSGLOBAL INPUTS
RECEIVER
REVERSE LOOP SHADOW LOOP EXIT LOOP
REVERSE SHADOW EXIT
RESET
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFF—ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
MASTER
SLAVE
1
ON
2 3 4 5 6 7 8
SELECT
DIAMOND BOARD ADJUSTMENTS AND WIRING
Feature Selector Switches #1 - #8
The Feature Selector Descriptions:
NOTE: The power MUST be turned OFF before changing the features selector switches.
Switch #1: Slave/Master - Sets the operator to work as Master or Slave. Single operator
MUST be set to MASTER.
Switch #2: Gate Opening - designates left or right opening direction.
Switch #3: Motor Brake - If the ON position is selected, the gate will stop instantly when
the limit switch is activated. This is useful for uphill/downhill applications and on all fail-safe operators.
Switch #4: Reverse Loop - Sets the reverse loop to be normally open (NO) or normally close (NC). It is useful in fail-safe applications.
Normal setting is OFF (Normally Open).
NOTE: For switches #5 - #8: Switch #1 OFF - “Slave Setting”, see page 15 “Gate Delay Functions” for descriptions.
Switch #5: One Pass (ON/OFF) - This tailgating feature works with the reverse loop to allow only one vehicle to pass the gate. After the vehicle
passes, the gate closes instantly. If a second vehicle approaches, the gate stops. The gate resumes closing after the vehicle leaves.
Switch #6: Stop-Reverse (ON/OFF) - The radio feature allows the transmitter to work as a three-button station and is useful for a partial
opening. If selected, the first command will open the gate, the second command will stop the gate and the third command will close the gate.
Switch #7: Alarm Reset (ON/OFF) - If the ON position is selected, after the five minute “Shutdown” time period, the operator will reset and any
input will be accepted. Normally, the power must be turned off to reset.
Switch #8: Close Timer (ON/OFF) - Turns the close timer ON or OFF. See page 12.
Feature Selector
See below
M/S Phase
DO NOT remove jumper or operator will NOT function.
Designates communication between master and slave
operators only. M/S operators can be set for the same
or opposite phase, depending on operators
communication (can vary).
Reset Button
Press for soft reset of operator (reset board logic).
Turns OFF activated alarm. Try this button before
preforming a hard shutdown of operator (turn
power switch OFF/ON) when operator fails.
Close Timer - See page 12
or
M/S Gate Delay - See page 15
Reverse ERD Sensor
See page 12
Limit Switches
See page 10
Global Inputs
Descriptions - See page 13
Wiring Accessories - See page 14
Outputs
See page 12
Fuse
15 Amp
250V
Slow-Blow
Factory Set
ERD Sensor
“Fine Tune”
Adjustment.
Please call
Eagle
Access
before any
adjustment.
See page 12.
Master/Slave
See page 15
3-Button Station
Cycles Operator
Radio Receiver
See page 13
In-Ground Loop Wires Connection
Connect in-ground loop wires to
corresponding loop detector Only when
using Eagle Plug-In Loop Detectors.
Loop Detector
EG167
Sensitivity
Indicators
Push & hold Reset/Sen. button
LED will blink from 1 to 4 times. Release
button upon reaching desired sensitivity.
1 = Very Low, 2 = Low,
3 = Normal, 4 = High
To change from inductive loop to
mini-loop- see instructions.
Green - Steady indicates power
Fast blink - Shorted loop
Slow blink - Open loop
Red - Detect Indicator
EG167
Power
Detect
Reset
Vehicle
Detector
EG167
Power
Detect
Reset
Vehicle
Detector
Eagle Plug-In
Loop Detector
Connections
See instructions
on the Eagle loop
detectors when
using them.
Eagle Plug-In
Loop Detector
Automatically adjusts for
proper sensitivity. Eagle
brand are designed for
“Fail-Safe” operation.
Switches #5 - #8: Switch #1 ON - Master Setting ONLY