Diamond DC Board Troubleshooting
Diamond DC Board Troubleshooting
Gate stops and
reverses direction
in mid cycle and
the OVERLOAD
LED remains ON.
(A) Gate operator is not plumb and level.
(B) ERD current sensor may be set too sensitive.
(C) Gate encountered an obstruction while cycling.
(A) The radio receiver’s LED remains on.
(B) One or more of the global input LEDs remain active.
(C) Gate has re-opened because in encountered an
obstruction while closing.
(D) The loop detector LED is on.
(E) Switch #8 is not functioning.
(A) The radio receiver or remote control has
malfunctioned in the “ON” position.
(B) Check global inputs for a short circuit.
(C) Only Key/Keypad will resume normal operation.
(D) Reset loop detector. Verify correct loop wiring. Set
loop detector to a different frequency and/or change the
sensitivity of the loop detector.
(E) Be sure Switch #8 is in the “ON” position.
(A) Motor Overload LED is on.
(B) Radio receiver is not “ON” when the remote
control button is activated.
(C) The green “Power” LED is off.
(D) The Fuse is blown.
• Feature selector Switch #1 MUST be set to the “MASTER ON” position unless the operator is being used as a slave operator.
• Feature selector Switch #3 (Brake) MUST be set to the “OFF” position.
• Safety external loop detector must be connected to the “REVERSE LOOP” input (see pages 25 & 26).
• If the CLOSE TIMER feature is desired, switch #8 MUST be in the “ON” position.
• It is OK to call the Eagle Access Customer Service Department with any questions... we are here to serve YOU!
1-800-708-8848
(A) Let motor cool down.
(B) Radio receiver has malfunctioned in the “OFF”
position.
(C) Turn on operator power switch and/or reset the main
circuit breaker.
(D) Check and/or replace the fuse with same amp fuse.
(A) Remount operator.
(B) Turn the ERD current sensor slightly in the
clockwise direction.
(C) Check and remove all obstructions
Gate will not close.
Gate will not open.
SYMPTOMS PROBABLE CAUSE
COMMON OVERSIGHTS TO BE AWARE OF:
REMEDY
Diamond DC Board ONLY