15
Diamond Board Master / Slave Setup
BY EAGLE ACCESS CONTROL SYSTEMS, INC. BY EAGLE ACCESS CONTROL SYSTEMS, INC.
IMPORTANT: The 115 VAC power for the master and slave operators MUST be on the same circuit breaker.
It is recommended that each gate operator’s initial set-up is completed (Direction of gate travel, limit
switches, ERD reverse sensor and feature selector switches #1 - #4) before connecting the operators
together. After each operator functions individually, proceed to Master/Slave connection and operation.
NOTE: #1 & #2 switch settings are
based on the illustration above.
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFF—ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
MASTER
SLAVE
1
ON
2 3 4 5 6 7 8
SELECT
MASTER
Operator
SLAVE
Operator
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFF—ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
MASTER
SLAVE
1
ON
2 3 4 5 6 7 8
SELECT
Connect Master and Slave Operators Together
Choose your board type and use 20 GA stranded wire.
Correct polarity is VERY important. DO NOT cross
polarity. Operators will NOT function properly if not
wired correctly.
SLAVE MASTER
+ – + –
#14#13
COMM PORT
SLAVE MASTER
+ – + –
#14#13
COMM PORT
Use the feature selector to choose #2 - #8
options for the master operator. Switch #1
MUST be ON. Refer to page 9 for more
information about each of the features.
Use the Close Timer (#8 ON) on the
master board only to set the gates
closing time 1 - 60 seconds.
Use the feature selector to choose #2 - #3
options for the slave operator. Switch #1
MUST be OFF. Switch #4 is not used.
Refer to page 9 for more information
about each of the features.
If NO gate delay is needed:
Switches #5 - #8 MUST be OFF.
Setting the OPEN Delay Feature:
#5 OPEN DELAY S: Turning #5 - ON delays opening the SLAVE gate by 1.5 seconds.
# 6 must be turned OFF. This is useful for magnetic lock applications.
#6 OPEN DELAY M: Turning #6 - ON delays opening the MASTER gate by 1.5 seconds.
# 5 must be turned OFF. This is useful for magnetic lock applications.
Setting the CLOSE Delay Feature:
#7 CLOSE DELAY S: Turning #7 - ON delays closing the SLAVE gate by 1 - 6 seconds,
adjustable by the close timer on the slave board. #8 must be turned OFF.
#8 CLOSE DELAY M: Turning #8 - ON delays closing the MASTER gate by 1 - 6 seconds,
ad
ustable b
the close timer on the slave board. #7 must be turned OFF.
ACCESSORIES NOTE: The Diamond Board
allow you to connect accessories to the master
or slave boards).
See page 14 for accessory wiring connections.
Opens to the Left Opens to the Right
Feature Selector (Master Operator)
Close Timer (Master Operator)
Feature Selector (Slave Operator)
MASTER
OPEN RIGHT
BRAKE ON
REVERSE LOOP NC
ONE PASS
STOP-REVERSE
ALM-RST
CLOSE TIMER
OFF—ON
SLAVE
OPEN LEFT
BRAKE OFF
REVERSE LOOP NO
OPN DLY S
OPN DLY M
OPN DLY S
OPN DLY M
MASTER
SLAVE
1
ON
2 3 4 5 6 7 8
SELECT
Feature Selector (Slave #5 - #8)
Switch #1 MUST be OFF (Slave Operator)
Gate Delay Functions
For overlapping bi-parting gates
Diamond
Board
ONLY
(Slave Operator)
Diamond
Board
ONLY
(Master Operator)
TIMER
MIN
MAX
TIMER
MIN
MAX
Close Timer on the
slave operator
1 - 6 seconds
Diamond Board Master / Slave
Diamond Board ONLY