IL17569
Page 12-8
Effective June, 2001
Table 12.6 Event Operate Cause Table — continued
Cause Cause Description Value Given
55A PF Apparent Power Factor has operated Miscellaneous Trip Status – contains the status flags
that describe all unbalance, frequency, breaker failure,
power factor, and zone interlocking trips
55D PF Displacement Power Factor has operated Miscellaneous Trip Status – contains the status flags
that describe all unbalance, frequency, breaker failure,
power factor, and zone interlocking trips
Zin Trip Zone Interlock Trip has operated Miscellaneous Trip Status – contains the status flags
that describe all unbalance, frequency, breaker failure,
power factor, and zone interlocking trips
PwrAlm The system alarm for Watt, VA, System Alarm Timeout Status – contains
or VAR has operated the status flags for all system alarm timeouts
PwrDmdAlm The system alarm for Watt demand, System Alarm Timeout Status – contains the status
VA demand, or VAR demand has operated flags for all system alarm timeouts
CurDmdAlm The system alarm for Current System Alarm Timeout Status – contains the status
Demand has operated flags for all system alarm timeouts
THD CurAlm The system alarm for Current Total System Alarm Timeout Status – contains the status
Harmonic Distortion has operated flags for all system alarm timeouts
THD VolAlm The system alarm for Voltage Total System Alarm Timeout Status – contains the status
Harmonic Distortion has operated flags for all system alarm timeouts
BrkOpAlm Breaker Operation Alarm, the number System Alarm Timeout Status – contains the status
of breaker operations has exceeded flags for all system alarm timeouts
the programmed limit
AccuCurAlm Accumulated Current Alarm, the System Alarm Timeout Status – contains the status
accumulated interrupted current the flags for all system alarm timouts
breaker has opened has exceeded the
programmed limit
Any contact input state change can be logged in the Event log if so programmed. Each input can be logged or not logged according to the
program settings (see Section 5). The value given for each event is: Active for an input transition of low to high, or inactive for an input
transition of high to low. Table 12.7 summarizes the contact input causes for an event log.
Table 12.7 Event Input Cause Table
Cause Cause Description Value Given
Cin1State Alt Contact Input 1 State changed Active or Inactive
Cin2State Alt Contact Input 2 State changed Active or Inactive
Cin3State Alt Contact Input 3 State changed Active or Inactive
Cin4State Alt Contact Input 4 State changed Active or Inactive
Cin5State Alt Contact Input 5 State changed Active or Inactive
Cin6State Alt Contact Input 6 State changed Active or Inactive
Cin7State Alt Contact Input 7 State changed Active or Inactive
Cin8State Alt Contact Input 8 State changed Active or Inactive