Advantage IV and EB-Flow2 Product Lines
O&M MANUAL
Section 2 Startup
2-O&M_Startup_r1l Section 2Page 1
EBTRON, Inc • 1663 Hwy 701 S., Loris, SC 29569 • Toll Free: 800-2EBTRON (232-8766) • Fax: 843-756-1828 • EBTRON.com
2. SECTION OVERVIEW
This section discusses startup and basic operation. Advantage IV and EB-Flow2 remote transmitters are
“plug-and-play.Transmitters are designed to be fully functional at power-up. Field configuration is generally
only required when factory default output signals and/or network parameters must be modified for the host
building automation system or application controller.
2.1. PRE-POWER CHECKS
2.1.1. Sensor Probe Installation
Inspect and verify the following:
The location where the probes are located meet or exceed EBTRON published placement guidelines
for the sensor probe model and sensor density provided.
If minimum placement guidelines cannot be achieved, installed accuracy may be compromised.
Transmitters can be field adjusted to match a third-party measurement. Adjusted field measurements
typically result in comparative readings within ±3% of the third-party measurement. Be advised that
the third-party measurement may have uncertainties greater than or equal to ±10% and should only
be used to adjust the airflow measurement device if the probes do not meet minimum placement
requirements and the discrepancy is greater than the uncertainty of the third-party source.
Inspect and verify the following:
The probes are properly spaced in the fan, duct or opening.
The airflow directional arrow is pointing in the direction of airflow and the sensor probes are not
twisted in the airstream.
All sensor probes are properly connected to the transmitter.
2.1.2. B.A.S. and Other Connections
Advantage IV and EB-Flow2 product lines are available with a wide variety of interface options. The
connectivity capability provided is indicated by the model code for the x placeholder in the model code. The
base model codes are as follows:
Advantage IV Product Line
o Gold Series
GTx116
GTx116e
GTx208e
GTx108
GTx108e
GTx204e
o Hybrid Series
HTx104
HTx202