The data, information and descriptions, and the technology described herein are the exclusive intellectual property of Snap-on Climate Solutions S.r.l. and
constitute industrial secrets. Said information is communicated in strict confidentiality; said information may be used only for the purpose for which it is
communicated; said information may not be divulged, communicated, or revealed to third parties and/or reproduced by any means for any reason whatsoever; said
information is protected under applicable Italian competition and industrial property law.
Service manual Cinquecento12 (VA21) [MANUY2V.SB0] ed.1 ver.0.1.doc pag.91 - 09/11/2021
Recovery phase the pressure
drops to 0 and the procedure
is interrupted.
-Check if you read pressure in
LP and HP gauge.
-Check that the pipes and
connectors are tight.
-Replace the external bottle
with a full one
During recovery compressor
does not stop working and
HP and LP pressure gouges
read 0 bar
-Verify the sealing of the EV6
valve. Make sure valve is
clean.
-Check if compressor reaches
20 BAR . If not replace it.
Please contact the Technical
Support from ACS24.
EMPTY EXTERNAL
BOTTLE ALARM
MACHINE DOES NOT
FINISH THE
RECOVERY