Problem
Solution
Relative
pressure does
not agree with
official
reporting
station
Relative pressure refers to sea-level equivalent
temperature and should generally agree closely with the
official station. If there is a disagreement, make sure you
are not looking at absolute pressure, in particular if your
station is not near sea level. Also check at different times
due to occasional delays in updates to the official station.
Redo the pressure calibration procedure described in
section 5.3.1.
The barometer is only accurate to ± 0.09 inHg (3 hPa)
within the following relative pressure range: 20.67 to
32.50 inHg (700 1,100 hPa), which corresponds to an
altitude of 9,000 ft. (2,750 m) down to 2,500 ft. (750 m)
below sea level. At higher altitudes, you should expect a
possible lesser accuracy and non-linearity effects in the
error (the calibration offset only allows for a partially
linear correction).
Time is
incorrect
Make sure your time zone and daylight savings time
setting is correct (even when connected to the Internet via
Wi-Fi this is needed). If not connected to the Internet via
Wi-Fi, you may also have to manually set the correct time.
Display console
brightness is
weak
Adjust brightness using setup functions, or place console
in a darker location.
Data not
reporting to
Wunderground.
com
Confirm your station ID is correct. The station ID is all
caps, and the most common issue is substituting a capital
letter O for a 0 (zero) or vice versa. Please note the digit 0
can only occur in the last part of the station ID (which is a
station number in a city). Example, KAZPHOEN11, not
KAZPH0EN11
Confirm that your password (also called: key) is correct. It
is the password wunderground.com generated for your
station ID. You can also verify it by logging in to
wunderground.com and looking it up under “My PWS.
Make sure the date, time and time zone is correct on the
console. If it is not incorrect, you may be reporting data
for a point in the past or future and you may not see it
where you expect it.
Check your router firewall settings. The console sends