2 - 16 AG45134 Rev. 3
IMAGE LENGTH
OPTIONS 0.027” to 39.330” or 2 mm to 999 mm
This parameter specifies the length of the test pattern to be
recorded.
IMAGE OFFSET (VERTICAL)
OPTIONS 0.0000” to 39.330” or 0 mm to 999 mm
This parameter specifies the distance from the leading edge of
the plate to the first line of the image.
HORIZONTAL RESOLUTION
OPTIONS (dpi) 1200, 1270, 1800, 2400, 2540,
3048 and 3556.
(dpmm) 47.2, 50.0, 70.8, 94.5, 100.0,
120.0, 140.0
By picking any of the optional values, you set the horizontal
resolution to that value. Horizontal Resolution is not displayed
if a GRID test pattern is selected.
Note: Resolution is model dependent. Your options may differ
from those listed above.
VERTICAL RESOLUTION
OPTIONS (dpi) 1200, 1270, 1800, 2400, 2540,
3048 and 3556.
(dpmm) 47.2, 50.0, 70.8, 94.5, 100.0,
120.0, 140.0
By picking any of the optional values, you set the vertical
resolution to that value. Vertical Resolution is not displayed if a
GRID test pattern is selected.
Note: Resolution is model dependent. Your options may differ
from those listed above.