94
Section F - Ice Maker
Complaint-Ice Maker Continues to Eject When Container is Full.
1. Check for loose linkage to the Ice Maker Control arm Shut-Off Switch. Switch
should open when arm is in raised position. Adjust, if required.
2. Check Shut-Off Switch terminals “C” and “NO” for continuity with Ice Maker
Control Arm raised. Replace switch if continuity readings are indicating
a closed circuit.
Complaint-Ice Maker Produces Undersized Ice Pieces
1. Ensure that Ice Maker mold is level.
2. Check for partial restriction in supply line or Water Valve Strainer.
3. Ensure that the water pressure to Water Valve is sufficient. (20 psi min., 120
psi max.)
4. Ensure that the Water Valve Switch is adjusted for proper water fill, 78 to 83
cc’s.
5. Check thermal bond between Thermosat and Mold. If necessary, rebond with
thermal mastic sealer.
ICE MAKER TESTING PROCEDURES
Operating Cycle
The operation of the Ice Maker, water refilling, and
controlled ice storage, require proper functioning and
timing of all components.
Consider the following:
• Has refrigerator been properly installed and
connected to sources of electrical power and water?
• Has Freezer compartment Evaporator pulled down
to temperature?
• Have several ice making cycles been completed
and is the Ice Maker in the Freeze Cycle?
• Is the Ice Maker Thermostat single-throw switch in
series with the Mold Heater?
• Do the Ejector Blades make two revolutions per cycle? Is ice stored on
blades after harvest?
• Is the Water Solenoid wired in series with the Mold Heater?