30 Section C - Electronic Controls
Over Temperature Shut Off
Compressor operation is terminated at ambient temperatures over 85°C (185°F).
Compressor operation continues at 65°C (149°F).
User Interface - Version B (One position read out for freezer and food Compartment)
Freezer
Temperature Colder key increments setting one number each key press. Setting
Upper Limit = 9
Temperature Warmer key decrements setting one number each key press. Setting
Lower Limit = 0 (Off).
Number Setting to Temperature Conversion
0 = Off (All Loads. Damper Closed). Displays = “0”.
1 = +6°F (-14°C).
2 = +4 (-15.5°C).
3 = +3 (-16°C).
4 = +2 (-17°C).
5 = 0°F (-18°C).
6 = -2°F (-19°C).
7 = -3°F (-19.5°C).
8 = -4°F (-20°C).
9 = -6°F (-21°C).
Displays are off when Fresh Food Door is closed. Communications remain active.
Default = 5.
Fresh Food
Temperature Colder key increments setting one number each key press. Upper
Limit = 9
Temperature Warmer key decrements setting one number each key press. Lower
Limit = 1.