20
Service Manual
Air circulation
A Warm moist air
B Cold air
C Hot dry air
Heat pump
1 Compressor
2 Condenser
3 Evaporation unit
4 Heat exchanger
5
Solenoid valve
6 High pressostat
7 Low pressostat
8 Check valve
9 Drying filter
10 Expansion valve
11 Pressure operating water control valve
12 Fan
Refrigerant
a
Vapour, high pressure
b Liquid, high pressure
c
Liquid, low pressure
d Vapour, low pressure
9.4 Separating the units
If needed, it is possible to separate the tumble dryer from the heat pump unit:
• Disconnect the power to the machine.
• Disconnect the water and drain hoses.
• Demount the tumble dryer by unscrewing the screws on each side.
• Open the door and demount the screws on top of the the heat pump unit door.
• Open the heat pump unit door and disconnect the cable.
• Carefully lift off the tumble dryer from the heat pump unit.