20
Service Manual
Air circulation
A Warm moist air
B Cold air
C Hot dry air
Heat pump
1 Compressor
2 Condenser
3 Evaporation unit
4 Heat exchanger
5
Solenoid valve
6 High pressostat
7 Low pressostat
8 Check valve
9 Drying filter
10 Expansion valve
11 Pressure operating water control valve
12 Fan
Refrigerant
a
Vapour, high pressure
b Liquid, high pressure
c
Liquid, low pressure
d Vapour, low pressure
9.4 Separating the units
If needed, it is possible to separate the tumble dryer from the heat pump unit:
Disconnect the power to the machine.
Disconnect the water and drain hoses.
Demount the tumble dryer by unscrewing the screws on each side.
Open the door and demount the screws on top of the the heat pump unit door.
Open the heat pump unit door and disconnect the cable.
Carefully lift off the tumble dryer from the heat pump unit.
fig.8006