DOC. NO. 5956.573.05 P. 2 3 / 8 8
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
The PREWASH MODULE / family parameters are described below:
:
(**) The difference between the max water level and the hysteresis level must be higher than the working level:
Stanby level - Max lev. hister > Working level
>
(**) The difference between the max water level during washing phase and the hysteresis level must be higher than the working level:
Run level - Max lev. hister > Working level
>
(**) The difference between the max water level during drain cycle and the hysteresis level must be higher than the working level:
Drain max level - Max lev. hister > Working level
>
Modular
parameter
Compact
parameter
Family
Nr.
Param
eter
Nr.
Parameter description Unit of
measure
Min Max Factory
setting
[for
WTM200
(*)]
Prewash
module
4 0 Type of prewash module
Modular Rack Type:
- 0/“1165-600” module from 1165 mm or from 600
mm
- 1/“1490” module from 1490 mm.
- - - 1165-600
Compact Rack Type:
- “0” module from 1165 mm, from 600 mm, from 44”
or from 22” “0” module from 1165 mm or from 600
mm
- “1” module from 1490 mm (
meaningless for compact
RT).
“1” module from 1490 mm.
--- 0
Stanby
level
(**)
4 1 Indicates the maximum level in the prewash tank. The
filling stops when the water level reaches this value.
mmH2O 60 400 220
Run level
(**)
4 2 The value for the maximum level is modified from
“Stanby level” to “Run level” during prewashing phase
in order to avoid water loss when the pumps stop.
mmH2O 60 400 180
Drain max
lev.
(**)
4 3 Meaninful only during “Drain and clean” cycle.
Indicates the maximum level during “Drain and clean”
cycle.
mmH2O 60 400 190
Max lev.
hister.
(**)
4 4 Indicates the hysteresis level relative to the maximum
level in the prewash tank. It is related to the “Stanby
level” , to the “Run level” and to the “Drain max lev.”.
mmH2O 0 80 30
Working
level
(**)
4 5 Indicates the water level in the prewash tank enabling
the prewash tank heating elements and the prewash
pumps operations.
mmH2O 60 400 90
Tank
temper.
4 7 Tank temperature set point. °C / °F 0/32 90/
194
0/32
Sanit.
temper.
4 8 Tank temperature set point during sanitization phase
(only on machines with sanitization - N.B.: heating
element must be installed in prewash module).
°C / °F 10/
50
90/
194
75/167
Histesys
temp.
4 9 Hysteresis temperature relative to tank temperature
set point.
°C / °F 1/2 50/
90
5/9
Prew.
san.
durat.
4 10 Duration of wash tank cleaning phase during a
sanitization cycle.
sec 0 250 60
Drain
delay
4 12 Time between reaching level “0” (air trap level) in the
tank and closing of the drain solenoid valve; allows
complete emptying of tank.
sec 0 200 30
Autom.
drain del.
4 13 Time between two automatic water changes. If this
parameter is set at zero the function is disabled.
min 0 250 50
Water to
drain
4 14 Quantity of water to be drained with each automatic
emptying.
mmH2O 0 50 10 (****)
Max
temper.
prew.
4 15 Max permissible temperature in prewash tank. If the
tank temperature exceeds the set temperature, a
quantity of water equal to the quantity set by means
of the "Water to drain" parameter is drained.
If this parameter is set at zero the function is
disabled.
°C / °F 0/32 99/
210
40/104
Pulse/lit
prewash
4 16 Indicates the impulses per litre characterising the
possible flow meter connected to the prewash
module feed.
The rating plate data of the flow meter used.
P/Lit 0 999 0
Warning
lev prew.
4 17 Indicates the max. level allowed in the wash tank
before the start of an automatic draining cycle. To
prevent water spilling from the door in case of
clogging of the overflow due to dirt.
mmH2O 180 400 270