EasyManua.ls Logo

Electrolux WTCS90ERB - B1 Specific Functions

Electrolux WTCS90ERB
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC. NO. 5956.573.05 P. 5 9 / 8 8
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
B1 SPECIFIC FUNCTIONS
B1.1 SETTING UNIT OF MEASURE IN FAHRENHEIT
The machines leave the factory with the unit of measure used for displaying temperatures in degrees Celsius
(Fahrenheit vis. = No only for Modular Rack Type and
 only for Compact Rack Type).
To set the unit of measure used for displaying temperatures in degrees Fahrenheit, enter in GENERIC FUNC.
and set the Fahrenheit vis. parameter = Yes (only for Modular Rack Type) or enter in
 and set the 
parameter to (only for Compact Rack Type).
B1.2 LANGUAGE SETTING
The factory-set language on modular machines is English. Set the required language using the “LANGUAGE”
parameter in the “USER SETTINGS” family.
B1.3 “MAX. MOTOR CURR.” PARAMETER (  ) SETTING
1. Wait until the machine, complete with tables, is ready for a wash cycle.
2. Start a wash cycle and read the current absorbed by the gear motor
( refer to par. A1 “DISPLAY OF AUXILIARY VALUES”).
3. Add 2 to the read value (e.g. if “Motor current” = 34 ---> 34+2=36 decA).
4. Set the “Max. motor curr.” parameter with the value thus obtained.
B1.4 MAX. TANK TEMPERATURE PARAMETER SETTING IN PREWASH FAMILY
If the machine is provided of the prewash module with sanitation kit, it is possible configure the prewash like
an additional wash module. To do this, set the “Tank temper.” (
) parameter, that you can find in the pre-
wash family (
), to the temperature value requested. Doing this, during the normal wash phase, the heat-
ing element of prewash will heat the water in the tank to the temperature set.
WARNING:
If the “Tank temper.” () parameter in the prewash family () is set to a value higher than 0:
you must set to 0 the “Max temper. pre” () parameter to disable the dump and fill function in
the prewash tank when the water temperature exceed the “Max temper. pre” () value;
it is possible that there is a partial reduction of the performance with some type of food;
the manual scraping of the dishes is strongly recommended before you put them on the machine
WARNING:
Make sure that the power supply system is suitable, because the total power consumption will be 9 KW
higher than to what written in the rating plate.
WARNING:
The Rack Type leaves the factory with the “Max motor curr.” parameter already set to the optimum
value. Reset it only when replacing a PCB or the gear motor.
WARNING:
The “Max motor curr.” () parameter indicates the max. current deliverable to the gear motor by the
inverter only if automatic current setting was not carried out (see paragraph A4.8 MOTOR ADJUST-
MENT); if this parameter is modified, the max. current values calculated with the automatic setting
procedure no longer have any effect on operation but the new current limit is represented by the “Max
motor curr.” () parameter.

Table of Contents