DOC. NO. 5956.573.05 P. 7 3 / 8 8
Electrolux
EFS - Dishwashing Systems Platform
Electrolux Professional
UFr Ir compensation 50
nCr Nominal motor current 3.6
CLI Current limit 3.9
nSL Nominal motor slip 5
SLP Slip compensation 100
COS Nominal motor cosine 0.65
FUn tCC ACt Type of control 2C
tCt Type of two wire control Lel
rrS Reverse nO
Ps2 LIA Preset speed lia nO
LIB Preset speed lib nO
HSP LIA Config. input Lia nO
LIB Config. input Lib nO
tLS 0.0
PI PIF nO
LOC Overload threshold 90
tOL Time delay for overl. func. 0
API Histeresis freq. reached 0.3
LUL Underload threshold 60
tUL Time delay for underl. func. 10
rSF Fault reset nO
rP2 LI Second ramp nO
LC2 LI 2nd limit current nO
nST Freewheel stop nO
StP Controlled stop on loss of line FST
brA Deceleration ramp adaptation YES
AdC ACt Automatic dc injection YES
tdC Injection time on stopping 0.5
SdC Injection current 2.9
SfT ACt Frequency range LF
Sfr Switching frequency 4
FLr Catch on the fly nO
dO ACt Analogic output do OCr
Atr Automatic restart nO
bFr Motor frequency 50
SCS Configuration backup nO
FCS Reminder of the configuration nO
Parameter Description Standard machine