When the scanner works in this mode, it can also according to the trigger electrical level to enter the
reading state. After the trigger electrical level is canceled or reading times out, it will re-enter the
state of monitoring scene change. Before re-entering the monitoring state, the trigger electrical level
needs to be canceled, then it will be switched to the sensing mode.
Sensing Automatically
Sensitivity
Normal (Default) Fast
Ultra-fast
Single Reading Time
In sensing reading mode, the parameter indicates the maximum time of allowing reading engine to
continuously collect and identify barcode before reading successfully. After reading successfully or
single read timeout, the reading engine will enter the interval of not collecting the read. The range of
single read time is 0.1~9.9s, step length is 0.1s. When set to 0, the read does not wait. Default time
is
1s. Please refer to the Chapter 7 for the setting method.
Continuous Mode
Continuous mode means that the scanner continuously shoots, reads and output the information. In
this mode, the same barcode cannot be output.