EasyManua.ls Logo

Element P100 - Version Number-HYRS_RE; General Settings (Default HID Single Scan Mode); Host Mode; Trigger Mode (Single Scanning, Scanning Continuously, Auto Sensing)

Element P100
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P100
User Manual
42
5 BYTES
1 BYTE
1BYTE~250BYTE
Set barcode Code 128 type Barcode
Prefix Fixed prefix: +N+S-
Operand The operand is the following command data
Data Indicates parameter data carried by this command
Version number——HYRS_RE
General settings (default HID single scan mode)
Host mode (CDC, HID, BT, COM
Operand: 0x41
USB Virtual Serial Port
USB Virtual Keyboard
BT
General Serial Port
Data
0x02
0x01
0x03
0x04
Set scanner interface mode
Trigger mode (Single scanning, scanning continuously, auto sensing)
Operand: 0x42
Button Trigger
Light continuously
Auto sensing
Data
0x00(Default)
0x01
0x02
Set the scanning mode of the scanner
Default parameters (Restore factory settings)
Operand: 0x43
Data: 0x00
Restore to default parameters of factory settings.

Table of Contents