EasyManua.ls Logo

Element P100 - Multi Code Sensitivity; Buzzer Enable; The Convert Rate in HID Mode; Timeout Setting of the same Barcode in Non-Single Scan Mode

Element P100
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P100
User Manual
45
Set whether to start scanning multiple barcode modes at the same time and set the number of
scanning barcodes simultaneously.
Multi code sensitivity
Operand: 0x4C
Level 1
2
3
......
9
10
Data
0x00
0x01
0x03
......
0x09
0x0A
Note: the higher the level, the stronger the ability to decode the double code, but the
corresponding time to decode the single code will be longer.
Buzzer enable
Operand: 0x4D
Enable
Disable
Data
0x01 (Default)
0x00
The convert rate in HID mode
Operand: 0x4E
Fast
Normal
Slow
Data
0x01
0x02 (Default)
0x0a
Timeout setting of the same barcode in non-single scan mode
Operand: 0x4F
Variable
Data
0x00~0x63
Data:
0x00 indicates that there is no Timeout Invalid. If there is a barcode, it can still output.
0x01 indicates the timeout of 100ms.
0x63 indicates the timeout 9.9s.