Chapter 4 – User Menu
EL2315D & EL2316D Door Controller Manual
Revision 1.1.21
63
Here, “01“ refers to Door 1, and “OFF“ shows that the door is NOT
released. To release Door 1, press key <F4> once, and the display
will change from “OFF“ to “ON“. If key <F4> is pressed again, the
display reverts back to “OFF“. When the desired setting is shown,
press <#> key to accept the selection. Now the display will show:-
The value “#2” indicates that we are now setting door 2 instead of
door 1. Follow the same procedure as described above for door 1
is used to open or close door 2.
The procedures for setting Inhibit Access is similar to that of setting
Permanent Lock Release. First, you must set the value for door 1,
then you can set the value for door 2. When “Inhibit Access” is set
to “ON”, all valid card holders are barred from entering.
The procedure for setting PIN mode is also similar to that of setting
Permanent Lock Release. First, you must set the value for door 1,
then you can set the value for door 2. When PIN mode is set to
ON, entry requires card plus PIN.
4.4.2
Anti-Passback Command
Anti-Passback has 4 options:-
OFF - Anti-Passback is not implemented
TMR (Timer) – Anti_Passback by Timer. A person is not
allowed to enter a door a second time until a specified
time has passed.
2RDR (2-Reader) – Anti-Passback by reader. The controller
keeps track of whether a person is inside or outside a room,
and bars him from coming in if he is already deemed to be
inside. Therefore, to implement this mode of Anti-Passback,
both entry reader and exit reader
01
Set Door
Lock
Param
ReL
OFF
02
Set Door
Lock
Param
ReL
OFF