1.1 MP110 Control unit
• Wire control unit for small and medium size plants
equipped with 8 zones max + 1 tamper input + 1
mechanical key input. Expandable up to 56 zones + 5
zones 24H + 4 AUX
5 programmable alarm outputs: 4 open collector electric
outputs and 1 relay output with free exchange.
Inputs can be partialized into 3 sectors
Possibility of controlling up to 4 readers, 4 keyboards
and 4 expansions for inputs/outputs via dedicated serial
line ( 4 conductors)
8 supplementary alarm zones + 1 tamper input + 1
auxiliary input in every input expansion which may be
of parallel type (EP100) or serial type (ES100). Every
expansion is also equipped with 4 open collector electric
outputs.
2 additional alarm zones in every reader and in every
remote keyboard
Programmable zones such as THEFT ( instant, delayed,
last output, GONG), Technologic, Fire, Silent panic,
panic with sirens.
Activation and deactivation via LCD display remote
keyboard (with clear message visualization), led remote
keyboard, integrated electronic key, mechanical key.
Signalling of :general alarm, failure, mains presence,
low battery, plant status, tamper alarm,inputs open, inputs
cut off. Signalling is provided by means of leds and/or
display.
8 user access codes are available: MASTER code,
installer code, remote surveillance code, user code 2, 5,
6, 7 and 8.
Max 64 events can be memorized
Alarm transmission integrated in the control unit
(MP110TG version) with 6 23-digit telephone numbers
communicator Multiprotocol digital transmission on 8
programmable channels. Optional voice transmission
(with SV108+KV100 module) with 9 messages (1 base
message + 8 alarm messages)
Programmable with KP100 led keyboard and KP100D
keyboard.
Programmable through local/remote PC and Fast Link
software.
Programmable commutating lock functions with open
zones and zone self-bypassing.
MP110M / MP110M TG
AVAILABLE VERSIONS
MP110
1.5 A supply, 12V-6Ah allocable
battery, fixed terminals, designed
for telephone interface.
MP110TG
1.5 A supply, 12V-6Ah allocable
battery, fixed terminals,
INTEGRATED telephone
interface.
MP110M
2.8 A supply, 12V-5Ah allocable
battery, extractable terminals,
designed for telephone interface.
MP110M TG
2,8 A supply, 12V-15Ah allocable
battery, fixed terminals,
INTEGRATED telephone
interface.
METALLIC BOX
PLASTIC
BOX
MP110 / MP110TG