TECHNICAL CHARACTERISTICS OF UNITS MP110 – MP110M – MP110TG
AND OF PS515 - PS28 (Meanwell S-40-15) POWER SUPPLY
- Rated power supply voltage
230V~ 50Hz +10 -15% (MP110M metallic version with PS28)
230V~ 50Hz +10 -15%
(plastic versions with PS515)
- Max current absorption 250mA (vers. with PS515), 500 mA (vers. with PS28)
- Unit board absorption at 12V 50mA at rest with balanced inputs
70 mA with inputs NC
- Max board absorption during alarm 65mA, at rest with balanced inputs
85 mA with inputs NC
- Unit operating voltage 10V5 to 15V-
- Rated voltage at PS515/PS28 power supply output 13,8V- adjustable
- Max current supplied by the PS515 unit 1.5A
- Max current supplied by the PS28 unit 2,8A
- Max ripple PS515 300mV p.p. with I = 1.5A
- Max ripple PS28 100mV p.p. with I = 2,8A
- Measured efficiency approx. 86%
- Current available for ext. devices 200 mA for versions MP110 to MP110TG
(keypads, sensors, horns) 550 mA for version MP110M
- Accumulator placed in plastic cont. 12V to 6.5Ah (Max 7Ah), versions MP110 to MP110TG
- Accumulator placed in metal cont. 12V to 15Ah (max 17 Ah ), version MP110M
- Anti-tamper 1A - 24V -
- Declared operating temperature -10°C to +55°C
- Certified CEI standard operating temp. +5°C to +40°C
- Guaranteed performance level I (with positive lines Not Connected)
II (with balanced or double balanced lines)
- Max length of unit-peripheral serialline 500 meters*(2x0.75 cable sect.for feeder + 2 x 0.22 x data)
- Max current supplied at electrical auxiliary indication outputs
(TC, panic,fire) 10mA
- Min/Max input time 0 sec to 90 sec at steps of10
- Output time same as input time + 10 sec
- Relay alarm time programmable between 30 s and 9 min
- Indication of optical (LCD) and electrical failure due to low unit battery, fuses, low expansion board supply
- Programmable output failure alarm time as long as failure lasts
- Run-down battery threshold adjustment 11.2 V to 11.4 V ± 5%
- Battery Test: automatic (only PS515) every hour and at switching to ON/OFF
- Degree of protection provided by casing IP30/ IK 02
TECHNICAL CHARACTERISTICS OF REMOTE KEYPADS KP100 - KP100D LINKED TO MP110 SYSTEM
- Rated power supply voltage 12V-(drawn from motherboard - serial line)
- Min/Max operating voltage 10V5 to 15V-
- Rated 12V input current(vers. KP100) 18mA (all sectors OFF;21mA all sectors ON;
48mA (all sectors ON + retro lighting; max 70 mA during test)
- Rated 12V input current(vers. KP100D) 21mA (all sectors OFF;31mA all sectors ON;
90mA (all sectors ON + retro lighting;max 105mA duringtest)
- Type of communication Elkron serial protocol
- Max length of serial line from unit 500 meters* (2x0.75 cable sect. for feeder + 2 x 0.22 x data)
- Max number of connectable keypads 4
- Series anti-tamper/anti-removal with clear indication addressed on unit
- Degree of protection provided by casing IP30 / IK 02
- Max number of possible combinations 100.000
66