EasyManua.ls Logo

Elkron MP110 - Technical Characteristics

Elkron MP110
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(((ELKRON))) - MP110
TECHNICAL CHARACTERISTICS OF UNITS MP110 – MP110M – MP110TG
AND OF PS515 - PS28 (Meanwell S-40-15) POWER SUPPLY
- Rated power supply voltage
230V~ 50Hz +10 -15% (MP110M metallic version with PS28)
230V~ 50Hz +10 -15%
(plastic versions with PS515)
- Max current absorption 250mA (vers. with PS515), 500 mA (vers. with PS28)
- Unit board absorption at 12V 50mA at rest with balanced inputs
70 mA with inputs NC
- Max board absorption during alarm 65mA, at rest with balanced inputs
85 mA with inputs NC
- Unit operating voltage 10V5 to 15V-
- Rated voltage at PS515/PS28 power supply output 13,8V- adjustable
- Max current supplied by the PS515 unit 1.5A
- Max current supplied by the PS28 unit 2,8A
- Max ripple PS515 300mV p.p. with I = 1.5A
- Max ripple PS28 100mV p.p. with I = 2,8A
- Measured efficiency approx. 86%
- Current available for ext. devices 200 mA for versions MP110 to MP110TG
(keypads, sensors, horns) 550 mA for version MP110M
- Accumulator placed in plastic cont. 12V to 6.5Ah (Max 7Ah), versions MP110 to MP110TG
- Accumulator placed in metal cont. 12V to 15Ah (max 17 Ah ), version MP110M
- Anti-tamper 1A - 24V -
- Declared operating temperature -10°C to +55°C
- Certified CEI standard operating temp. +5°C to +40°C
- Guaranteed performance level I (with positive lines Not Connected)
II (with balanced or double balanced lines)
- Max length of unit-peripheral serialline 500 meters*(2x0.75 cable sect.for feeder + 2 x 0.22 x data)
- Max current supplied at electrical auxiliary indication outputs
(TC, panic,fire) 10mA
- Min/Max input time 0 sec to 90 sec at steps of10
- Output time same as input time + 10 sec
- Relay alarm time programmable between 30 s and 9 min
- Indication of optical (LCD) and electrical failure due to low unit battery, fuses, low expansion board supply
- Programmable output failure alarm time as long as failure lasts
- Run-down battery threshold adjustment 11.2 V to 11.4 V ± 5%
- Battery Test: automatic (only PS515) every hour and at switching to ON/OFF
- Degree of protection provided by casing IP30/ IK 02
TECHNICAL CHARACTERISTICS OF REMOTE KEYPADS KP100 - KP100D LINKED TO MP110 SYSTEM
- Rated power supply voltage 12V-(drawn from motherboard - serial line)
- Min/Max operating voltage 10V5 to 15V-
- Rated 12V input current(vers. KP100) 18mA (all sectors OFF;21mA all sectors ON;
48mA (all sectors ON + retro lighting; max 70 mA during test)
- Rated 12V input current(vers. KP100D) 21mA (all sectors OFF;31mA all sectors ON;
90mA (all sectors ON + retro lighting;max 105mA duringtest)
- Type of communication Elkron serial protocol
- Max length of serial line from unit 500 meters* (2x0.75 cable sect. for feeder + 2 x 0.22 x data)
- Max number of connectable keypads 4
- Series anti-tamper/anti-removal with clear indication addressed on unit
- Degree of protection provided by casing IP30 / IK 02
- Max number of possible combinations 100.000