(((ELKRON))) - MP110
5.9 Mechanical Key
Programming
• The following procedure allows to specialize the mechanical key to
work in an impulsive manner or at level ( referred to negative).
• By programming the mechanical key to work at level, its OFF status prevails
over all other devices. This means that it is possible to enable the other
devices ( keyboards, readers) to modify the system status( ON,OFF,
PARTIALIZED) only if the mechanical key is ON.
1. Enter installer code.
2. Press twice key
+ key
to access procedure.
3. Press key
to change programming status. The input key function
mode is indicated in the following way on the display
LED KEYPAD LCD KEYPAD MODE
I PULSE KEY PULSE
L LEVEL KEY LEVEL
4. After selecting the desired option, exit by
The display visualizes the
current programming with:
I = Impulsive
L = at level
NOTE
WITH KEY PROGRAMMED AT
LEVEL YOU HAVE
INPUT OPEN = PLANT ON
IINPUT CLOSED = PLANT OFF
PROCEDURE ACCESS
INST
CODE.
5.8 Prealarm Signal Enabling
1. Enter installer code.
2. Press twice key
+ key
S
3. The current programming status is visualized on display.
- LED display shows letter "d" if the buzzer is disabled or "A" if
enabled.
- LCD display shows the message "PREALARM ON" if enabled or
message "PREALARM OFF" if disabled.
4. By pressing key
S
the status shifts from enabled to disabled and
viceversa.
5. By pressing key
you leave programming
• In this procedure it is possible to
enable or not the buzzer to the
acoustic signal of the input/output
time.
• If the buzzer is enabled to
signalling , it generates beeps at
1 second intervals throughout the
output time. During input time ,
frequence will be equal to about
2 beeps per second .
PROCEDURE ACCESS
INST.
CODE.
S
54