RC - Define Recorded Variables
Purpose:
Defines which signals are to be recorded.
The drive can record a range of signals for performance verification and debugging. The
first step of the recording process is the definition of the recorded variable by assigning a
value to RC, a bit field. Each “on” bit in the binary representation of RC defines a signal
to be recorded. The host can map many optional variables to any bit of RC from bit 0 to
bit 15.
A valid RC defines at least one recorded variable. Up to eight variables can be selected.
Attributes: Type: Parameter, Integer
Source: Program, RS-232, CANopen
Restrictions: Recorder inactive (RR=0 or RR=-1)
Default value: 0 (RS), Non-volatile
Range: See previous description
Unit modes: All
Activation: Next initiation of recorder (RR)
Notes:
If the drive has stored a previously-recorded data, setting RC will invalidate this
data. Invalidated data cannot be retrieved.
The total number of data points that may be recorded is fixed. Therefore, the
number of points per signal depends on the number of signals recorded
simultaneously: the more signals recorded, the fewer points available for each
signal.
See also:
RG, RL, RP[N], RR, BH
Reference chapter in the
SimplIQ Software Manual:
Chapter 7.4, ”The Recorder”
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-122