Elmo SimplIQ Series - HX - Hexadecimal Mode

Elmo SimplIQ Series
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HX - Hexadecimal Mode
Purpose:
Sets or resets the hexadecimal mode for reporting integer parameter values.
With HX=0, integers are reported as decimal numbers.
With HX=1, integers are reported as hexadecimal numbers.
HX does not affect floating-point reports.
The HX parameter allows easy reading of the digital inputs (IP), servo drive status (SR),
motor faults (MF), recorder settings (RC) and other variables that have the bit-field
attribute.
The HX parameter is not required for setting values. The commands BH=1024 and
BH=0x400 are equivalent, as 0x400 equals its decimal equivalent 1024.
Attributes: Type: Parameter, Integer
Source: RS-232
Restrictions: None
Default value: 0, Volatile
Range: [0, 1]
Unit modes: All
Activation: Immediate