LP[N] - List Properties
Purpose:
Sets the properties of the serial flash data upload and download by the next LS and DL
commands.
LP[1] sets the start byte address of the next LS transmission, or the byte address for
starting the storage of the next DL transmission.
LP[2] sets the size — in bytes — to be transmitted at the next LS.
LP[3] returns the start byte address of the user program (read only).
LP[4] returns the size of the user program storage (read only).
Attributes: Type: Parameter, Integer
Scope: RS-232, CANopen
Restrictions: None
Default values: LP[1] and LP[2] set to 0 on power on
Range: LP[1]: [0…262,144]
LP[2]: [0…247]
Index range: [1…4]
Unit modes: All
Activation: Immediate
See also:
CC, DL, LS
Reference chapter in the
SimplIQ Software Manual:
Chapter 6, ”Program Development and Execution”
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-85