EasyManua.ls Logo

Elmo SimplIQ Series - KI[N], KP[N] - PI Parameters

Elmo SimplIQ Series
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
KI[N], KP[N] - PI Parameters
Purpose:
KI[1], KP[1] defines the PI current control filter.
KI[2], KP[2] defines the PI velocity control filter.
KP[3] defines the gain of the position controller.
The parameters KP[2], KI[2] and KP[3] apply only if the controller gains are fixed (gain
scheduling is not used: GS[2]=0).
Attributes: Type: Parameter, Real
Source: Program, RS-232, CANopen
Restrictions: None
Default values: RS=0
Range: KI[N]>0
KP[N]>0
Index range: [1…3]
See also:
KV[N], GS[N]
Reference chapters in The
SimplIQ Software Manual:
Chapter 10, ”The Current Controller;” Chapter 15, “The Controller”
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-79