When a switch is released, the attached function terminates. Functions 2, 3 and 4
(Full Stop, RLS and FLS) do not change the drive reference command. When the
switch is released, the reference command (speed or position) is recovered. In
order to ensure that reference recoveries do not generate discontinuities, the SD,
VL[2] and VH[2] limits are used.
IP and IB[N] can be used to detect a logically active switch of all defined functions,
excluding function 2 (“No function is attached”).
Attributes: Type: Parameter, Bit-field
Assignment: Yes
Source: Program, RS-232, CANopen
Restrictions: None
Default value: IL[1]=0
IL[2…10]=7 (RS), Non-volatile
Range: According to previous description
Index range: [1…10]
Unit modes: All
Activation: Immediate
Reference chapter in the SimplIQ Software Manual:
Chapter 12, ” The Position Reference Generator”
See also:
UM, RM, JV, PX, BG, IP, IB[N], HM[N], HY[N]
SimplIQ Command Reference Manual Alphabetical Listing
MAN-SIMCR (Ver. 4.5)
3-74