39
15.2 Error Message
Error Description Reaction, error remedy
111 Probe cooking chamber 1
no signal
Operation stop!
Customer service call!
113 Meat probe
no signal sensor 1
Warning!
Customer service call!
Meat probe operation is possible!.
114 Meat probe
no signal sensor 2
Warning!
Customer service call!
Meat probe operation is possible!
115 Meat probe
no signal sensor 3
Warning!.
Meat probe operation is possible!
Customer service call!
116 Meat probe
no signal sensor 4
Warning!
Meat probe operation is possible!
Customer service call!
117 Water vapour elimination
sensor, no signal
Operation with a defective sensor is possible!
Customer service call!
127 Water vapour elimination
sensor, no signal
Operation with a defective sensor is possible!
Customer service call!
212
Over temperature STB
cooking chamber or motor
safety MI released
Operation stop!
Customer service call!
311
No water pressure
Cooking operation: Warning / autoclean: Pause Open water
valve. Remedy too low customer-side water pressure. Check
the pressure switch for proper functioning.Attention! The
appliance pauses in autoclean! The appliance can be used
without water in cookingoperation!
313
Hand shower off Activate Hand shower in the Service
511
Control module Warning!
PCB temperature above 65°C
Operation possible, Customer service call!
512
Control module Operation stop!
PCB temperature above 70°C
Customer service call!