51
Install - Step 14
Configure and register iSCSI connections
Configure an iSNS client on the storage system - Windows only
If your system uses an iSNS server, you must configure the iSNS client on the
storage system with Unisphere or Navisphere Manager.
• For Unisphere - Select All Systems > System List, and select a storage system for
which you want to establish an iSNS connection. From the System view, select
iSNS.
• For Navisphere Manager - In the Storage tree, right-click the icon for the storage
system for which you want to establish an iSNS connection, click iSCSI and then
click iSNS.
Configure iSCSI connections and register the server
Configure the logical connections between iSCSI initiator ports on each attached
server and the storage system’s iSCSI data ports (targets).
Network Interface Cards (NICs) use the Unisphere Server Utility to configure
connections; iSCSI host bus adapters use the QLogic SANsurfer utility.
For NICs
On each server that connects to the storage system with a NIC:
1. Open the Unisphere Server Utility:
Start > Programs > EMC > Unisphere > Unisphere Server Utility or Start > All
Programs > EMC > Unisphere > Unisphere Server Utility
2. Select Configure iSCSI Connections on this server and click Next.
3. Select Configure iSCSI Connections and click Next.