Install - Step 16 continued
Connect Fibre Channel data ports
CX4-120 Fibre Channel switch connection configuration
Applications such as MirrorView
/A, MirrorView/S, or SAN Copy software may restrict or require
the use of certain SP ports. Refer to the application documentation for specific cabling information.
Zone switches
If your configuration uses Fibre Channel switches without hard-wired zones, zone
them now. We recommend that you use single-initiator zoning, which limits a zone to
a single HBA port with one or more storage-system SP ports. Make sure that each
HBA is zoned to at least one port on each SP.