Fig.12: Pressure regulator, two-channel and single-channel
12 Pressure gauge connection for con-
nection 2
13 Pressure gauge connection for con-
nection 4
14 Blanking plug 15 Manometer
16 Lock nut 17 Adjustment screw for connection 2
18 Adjustment screw for connection 4
7.3 Shutoff module: Blocking the working pressure
The shutoff module and the air circuit should be tested monthly to en-
sure they function correctly.
7.3.1 Manually operated shutoff module
To block the operating line:
1. Use a screwdriver to turn the lock (18) 45° in an anticlockwise direction until it
releases. Then turn another 45°.
2. If necessary, protect the lock against unintentional actuation with a cable lock
for shut-off valves (material number: 7472D02758) or a lock. The hole diame-
ter is 5mm.
To unlock the shutoff module:
1. Remove the cable lock for shut-off valves or the lock.
2. Turn the lock 45° in a clockwise direction, then push the lock in up to the end
stop and turn it another 45° in a clockwise direction up to the stop.
18
Fig.13: Manually operated shutoff module
18 Lock
7.3.2 Pneumatically and electrically operated shutoff module
To release the operating line:
u Apply at least the minimum pressure P2, which corresponds with the pressure
on connections 2 or 4, to the pilot control connection to actuate the shutoff
module.
0 1 2 3 4 5 6 7 8 9 10
0
1
2
3
4
5
6
Working pressure [bar]
Fig.14: Working pressure diagram for pneumatically operated shutoff module
19
20
Fig.15: Pneumatically operated shutoff module
19 Sensor connection M8x1 20 Pilot control connection XØ4
20
30
Fig.16: Electrically operated shutoff module
30 Electronic pilot valve connection
M8x1
20 Pilot control connection XØ4
Pneumatically and electrically operated shutoff modules feature posi-
tion detection. A sensor with M8x1 connection can be used to query
the position.
Table3: Sensor data
Electrical data for the sensor
Behavior The sensor signal is supplied when no pilot air
is applied at the shutoff point, i.e. no air flows
through the operating line.
Output PNP
Max. current consumption 15mA
Min./max. voltage range 10…30V
Short-circuit proof yes
Voltage drop <2.5V
Protection class according to EN60529/
IEC529
IP67 for assembled connection
Table4: Pin assignment for sensor connection
Pin Assignment
1
4
3
1 0V
4 Output
3 +Vs
AVENTICS™ | R422003121-BAL-001-AE | English 17