Troubleshooting (continued)Table 2-1:
Error Recommended action(s)
- Restart the meter to install the firmware.
Daniel MeterLink prompts you with a
message that it must disconnect from
the meter. Once the firmware upgrade is
complete you will be able to reconnect
to the meter with Daniel MeterLinK.
- When the meter restarts, it takes about
two minutes before you will be able to
reconnect depending on the firmware
upgrade being performed. If the data-
base does need to be reinitialized, it
could take up to five minutes.
- After an upgrade, it is recommended to
reconnect to the meter and repeat the
Program Download process.
- If all the program components are suc-
cessfully updated, they will show to be
the same date and version as the Cur-
rently Installed Versions and the Down-
load button will be disabled.
- If one or more components are still not
updated, click Download to continue the
upgrade process.
No power to the unit
Check for correct voltage (10.4 - 36 VDC)
(refer to the System Wiring Diagram P/N
DMC-005324 in XREF Appendix).
Check the main power source for blown fuse
or tripped circuit breaker. Reference your
“as built” installation drawings for your loca-
tion.
One or more of the chords is not indicating a
reading (reporting zeros)
Check for loose connections at the cable
connectors.
Check the resistance of the transducers
(should be approximately 2 Ω).
Problem also may be caused by a bad Ac-
quisition Module or interconnect cable.
Check system status in the Daniel MeterLink
program for any flagged errors.
Check the CPU Module.
If Chord A is not indicating, Change the
transducer cables from Chord B to chord A.
If Chord B then fails, the transducers are bad
on Chord A.
Troubleshooting
24 Gas Ultrasonic Flow Meters

Table of Contents

Other manuals for Emerson Daniel 3410 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel 3410 Series and is the answer not in the manual?

Emerson Daniel 3410 Series Specifications

General IconGeneral
BrandEmerson
ModelDaniel 3410 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals