Parameter
description
protocol
Performance
Menu
6
Setting
this
parameter
to
0
will
disable
the
drive.
It
must
be
a
t
1
for
the
drive
to
run.
When
this
parameter
is
set
up
correctly
for
the
local
currency,
Pr
6.26
will
give
an
instantaneous
read
out
of
running
cost.
If
this
parameter
is
one
the
energy
meter
(Pr
6.24
and
Pr
6.25
)
is
reset
and
held
at
zero.
To
enable
t
he
feature
that
indicates
to
the
user
when
a
filter
change
is
due
Pr
6.18
should
be
set
to
the
time
between
filter
changes.
When
the
drive
is
running,
Pr
6.27
is
reduced
each
time
the
runtime
timer
hour
increments
(Pr
6.23
)
until
Pr
6.27
reaches
0,
at
whi
ch
point
Pr
6.19
is
The
powered
-
up
clock
always
starts
at
zero
each
time
the
drive
is
powered
-
up.
The
user
can
change
the
time
from
the
keypad,
serial
comms
or
an
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
set to 1 to inform the user that a filter change is required. When the user has changed the filter, resetting Pr
6.19
to 0 will indicate to the drive that the
change has been done and Pr
6.27
will be reloaded with the value of Pr
6.18
. Pr
6.27
can be updated with the value of Pr
6.18
at any time by setting
and clearing this parameter manually.
application module. If the data is not written with the various parts in the correct range (i.e. minutes are greater than 59, etc.) the clock is set to zero
on the next minute. This clock may be used for time stamping the trip log if Pr
6.28
= 0. This parameter is used in conjunction with Pr
6.21
.
Mentor MP Advanced User Guide
101
Issue Number: 4
www.onxcontrol.com
6.18
Time
between
filter
changes
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0 to 30,000 hrs
Default
0
Update
rate
Background read
6.16
Electricity
cost
per
kWh
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0.0
to
600.0
currency
units
per
kWh
Default
0.0
Update
rate
Background read
6.17
Reset
energy
meter
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background read
6.20
Powered-up
time:
years.days
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
1
1
Range
0 to 9.364 Years.Days
Update
rate
Background write
6.15
Drive
enable
Coding
B
it
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Default
1
Update
rate
4 ms read
6.19
Filter
change
required
/
change
done
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
Background read/write

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals