EasyManuals Logo

Emerson Mentor MP User Manual

Emerson Mentor MP
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
Menu
6
Parameter
Parameter
description
protocol
Performance
In
normal
operation
the
sequencer
has
been
designed
to
operate
with
Run
forward
/
R
un
reverse
controls,
or
with
a
Run
control
and
a
forward
Digital inputs connected to limit switches should be routed to these parameters if fast stopping is required at a limit. The drive will respond in 750
s
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
reverse selector. If Run forwards / Run reverse control is required then bits Pr
6.30
and Pr
6.32
should be used to control the drive (digital inputs
should not be routed to bits Pr
6.33
and Pr
6.34
). If Run control with a forward reverse selector is required then bits Pr
6.33
and Pr
6.34
should be
used to control the drive (digital inputs should not be routed to bits Pr
6.30
and Pr
6.32
).
The Run forward and Run reverse bits can be made latching by setting bit Pr
6.40
. The Not stop bit (Pr
6.39
) should be one to allow the sequencing
bit to be latched. If the Not stop bit is zero all latches are cleared and held at zero. The jog or jog reverse sequencing bits can also cause the drive to
run provided the motor is stopped when these bits are activated and the normal run sequencing bits are not providing a run signal.
(500 s digital input filter delay + 250 s software delay) and stop the motor with a zero deceleration ramp rate (i.e. in current limit).
The limit switches are direction dependant so that the motor can rotate in a direction that allows the system to move away from the limit switch.
Pre-ramp reference+hard speed reference > 0 rpm
Forward limit switch active
Pre-ramp reference+hard speed reference < 0 rpm
Reverse limit switch active
Pre-ramp reference+hard speed reference = 0 rpm
Both limit switches active
104
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
6.36
Reverse
limit
switch
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
250 s read
6.39
Sequencing
bit:
Not
stop
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
4 ms read
6.40
Enable
sequencer
latching
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
4 ms read
6.35
Forward
limit
switch
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
250 s read
6.37
Sequencing
bit:
Jog
reverse
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
4 ms read
6.34
Sequencing
bit:
Run
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Default
0
Update
rate
4 ms read

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals