Parameter
description
protocol
Performance
Menu
14
To
enable
the
PID
controller
the
drive
must
be
OK
(Pr
10.01
=
1)
an
d
the
PID
enable
(Pr
14.08
)
must
be
one.
If
the
option
enable
source
(Pr
14.09
)
is
If
Pr
14.18
=
0,
the
upper
limit
(Pr
14.13
)
defines
the
maximum
positive
output
for
the
PID
controller
and
the
lower
limit
(Pr
14.14
)
defines
the
Parameter
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
00.00 or routed to a non-existent parameter the PID controller is still enabled provided Pr
10.01
= 1 and Pr
14.08
= 1. If the optional enable source
(Pr
14.09
) is routed to an existing parameter the source parameter must be one before the PID controller can be enabled. If the PID controller is
disabled the output is zero and the integrator is set to zero.
minimum positive or maximum negative output. If Pr
14.18
= 1, the upper limit defines the maximum positive or negative magnitude for the PID
controller output. When any of the limits are active the integrator is held.
Mentor MP Advanced User Guide
183
Issue Number: 4
www.onxcontrol.com
14.10
PID
P
gain
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0.000 to 4.000
Default
1.000
Update
rate
Background read
14.13
PID
upper
limit
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
2
1
1
1
Range
0.00 to 100.00 %
Default
100.00
Update
rate
Background read
14.09
PID
optional
enable
source
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
2
1
1
1
1
Range
Pr
0.00
to Pr
22.99
Default
Pr
0.00
Update
rate
Read on reset
14.11
PID
I
gain
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0.000 to 4.000
Default
0.500
Update
rate
Background read
14.12
PID
D
gain
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
3
1
1
1
Range
0.000 to 4.000
Default
0.000
Update
rate
Background read
14.14
PID
lower
limit
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
2
1
1
Range
±100.00 %
Default
-100.00
Update
rate
Background read

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals