EasyManuals Logo

Emerson Mentor MP User Manual

Emerson Mentor MP
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #203 background imageLoading...
Page #203 background image
Menu
23
Parameter
Parameter
description
protocol
Performance
The
coding
defines
the
attributes
of
the
parameter
as
follows.
Defines
the
sub
block
headers.
Can
be
used
by
the
MP-Keypad
to
display
the
same
strings
as
the
SM-Keypad.
The
Binary
sum
of
Pr
23.03
to
Pr
23.09
.
To
be
used
by
the
MP-Keypad.
structure
Keypad and
format
Advanced
parameter
descriptions
Serial comms
Coding
200
Mentor MP Advanced User Guide
www.onxcontrol.com
Issue Number: 4
Coding
Attribute
{X.XX}
Copied
Menu
0
or
advanced
parameter
Bit
1
bit
parameter:
‘On’
or
‘OFF’
on
the
display
Bi
Bipolar
parameter
Uni
Unipolar
parameter
Txt
Text:
the
parameter
uses
text
strings
instead
of
numbers.
SP
Spare:
not
used
FI
Filtered:
some
parameters
which
can
have
rapidly
changing
values
are
filtered
when
displayed
on
the
drive
keypad
for
easy
viewing.
DE
Destination
pointer
parameter:
This
parameter
can
be
used
to
set
up
the
location
(i.e.
menu/parameter
number)
where
the
destination data is to be routed.
VM
Variable
maximum:
the
maximum
of
this
parameter
can
vary.
DP
Decimal
place:
indicates
the
number
of
decimal
places
used
by
this
parameter.
ND
No
default:
when
defaults
are
loaded
(except
when
the
drive
is
manufactured
or
on
EEPROM
failure)
this
parameter
is
not
modified.
RA
Rating
dependant:
this
parameter
is
likely
to
have
different
values
and
ranges
with
drives
of
different
voltage
and
current
ratings.
Parameters with this attribute will not be transferred to the destination drive by a SMARTCARD when the rating of the destination
drive is different from the source drive if the drive voltage ratings are different or the file is a parameter file. However, the value will be
transferred if only the current rating is different and the file is a differences from default type file.
NC
Not
copied:
not
transferred
to
or
from
SMARTCARD
during
copying.
NV
Not
visible:
not
visible
on
the
keypad.
PT
Protected:
cannot
be
used
as
a
destination.
US
User
save:
saved
in
drive
EEPROM
when
the
user
initiates
a
parameter
save.
RW
Read/write:
can
be
written
by
the
user.
RO
Read
only:
can
only
be
read
by
the
user
BU
Bit
default
one/unsigned:
Bit
parameters
with
this
flag
set
to
one
have
a
default
of
one
(all
other
bit
parameters
have
a
default
of
zero. Non-bit parameters are unipolar if this flag is one.
PS
Power-down
save:
parameter
automatically
saved
in
drive
EEPROM
when
the
under
volts
(UV)
trip
occurs.
Power-down
save
parameters are also saved in the drive when the user initiates a parameter save.
23.01
Sub
block
headers
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
1
Range
0
to
7
(USEr
(0),
SEt
UP
(1),
diAGnoS
(2),
triPS
(3),
SP
LOOP
(4),
SintEr
(5),
Fb
SP
(6),
inPut (7)
Default
USEr (0)
Update
rate
Background read
23.02
Binary
sum
of
pre
defined
sub
block
enables
Coding
Bit
SP
FI
DE
Txt
VM
DP
ND
RA
NC
NV
PT
US
RW
BU
PS
1
1
1
Range
0 to 127
Update
rate
Background read
Parameter
Value
23.03
1
23.04
2
23.05
4
23.06
8
23.07
16
23.08
32
23.09
64

Table of Contents

Other manuals for Emerson Mentor MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Mentor MP and is the answer not in the manual?

Emerson Mentor MP Specifications

General IconGeneral
BrandEmerson
ModelMentor MP
CategoryDC Drives
LanguageEnglish

Related product manuals