4.10.2 Wire the frequency input (externally powered)
Procedure
Wire to the appropriate input terminal and pins.
Figure 4-28: Frequency input wiring (externally powered)
A
D
B
C
7
8
A. Frequency input
B. Frequency input device
C. 1–10 KΩ resistance
D. 3–30 VDC
4.11 Wire Channels A and D for Safety Instrumented
Systems (SIS) applications
Use this procedure to wire Channels A and D for SIS applications.
Procedure
Use one of the following power options:
Channel A active (internal) power and Channel D passive (external) power
Channel A passive (external) power and Channel D passive (external) power
Wiring the channels Installation Manual
April 2022 MMI-20027478
40 Micro Motion 5700 Transmitters with Configurable Inputs and Outputs