A Wire the Micro Motion 5700 to the
Micro Motion 3100 transmitter
Prerequisites
• Set up the transmitter channel configuration to DO before wiring.
• Use active high and internal power.
• Use wire size 24 AWG (0,25 mm
2
) to 16 AWG (1,5 mm
2
).
Procedure
Tie the three ground pins of the 5700 together and then land on A14 of the 3100. The
ground pins are even numbers: 4, 6, and 8.
Example (see the following figure): Use relay 1 (C) and 2 (B) with Channels B and C, then
connect terminal 2 and 4 together from 5700 and land on A14.
Figure A-1: 5700 to 3100 - screw-type or solder-tail connector
F3
C A
IEC 127- 2
J 3
DISC
OUT 3
T5A 250V
C A
F1
C A
IEC 127- 2
J 1
J 4
MODEL 3300/3500
TERMINAL
CONNECTION
DS1
T5A 250V
K3 K2 K1
A B C
'
(
)
DISC
OUT 2
IEC 127- 2
F2 T5A 250V
J 2
DS2
DISC
OUT 1
DS3
1 2 3 4 5 6 7 8 9 10
A14
C18
C16
C14
This graphic sets Channel B, configured as digital output (DO)1, to relay 1. If a different
channel is assigned to DO, wire any DO to any relay.
A. Relay 3, DO 3 pins 6 and 7, C18
B. Relay 2, DO 2 pins 5 and 6, C16
C. Relay 1, DO 1 pins 3 and 4, C14
D. Channel D
E. Channel C
F. Channel B