A Wire the Micro Motion 5700 to the
Micro Motion 3100 transmitter
Prerequisites
Set up the transmitter channel configuration to DO before wiring.
Use active high and internal power.
Use wire size 24 AWG (0,25 mm
2
) to 16 AWG (1,5 mm
2
).
Procedure
Tie the three ground pins of the 5700 together and then land on A14 of the 3100. The
ground pins are even numbers: 4, 6, and 8.
Example (see the following figure): Use relay 1 (C) and 2 (B) with Channels B and C, then
connect terminal 2 and 4 together from 5700 and land on A14.
Figure A-1: 5700 to 3100 - screw-type or solder-tail connector
F3
C A
IEC 127- 2
J 3
DISC
OUT 3
T5A 250V
C A
F1
C A
IEC 127- 2
J 1
J 4
MODEL 3300/3500
TERMINAL
CONNECTION
DS1
T5A 250V
K3 K2 K1
A B C
'
(
)
DISC
OUT 2
IEC 127- 2
F2 T5A 250V
J 2
DS2
DISC
OUT 1
DS3
1 2 3 4 5 6 7 8 9 10
A14
C18
C16
C14
This graphic sets Channel B, configured as digital output (DO)1, to relay 1. If a different
channel is assigned to DO, wire any DO to any relay.
A. Relay 3, DO 3 pins 6 and 7, C18
B. Relay 2, DO 2 pins 5 and 6, C16
C. Relay 1, DO 1 pins 3 and 4, C14
D. Channel D
E. Channel C
F. Channel B