Cerabar M, Deltabar M, Deltapilot M Installation
Endress+Hauser 35
4.7.5 Seal for flange mounting
NOTICE
Distorted measurement results.
The seal is not allowed to press on the process isolating diaphragm as this could affect the
measurement result.
Ensure that the seal is not touching the process isolating diaphragm.
A0017743
Fig. 19:
1 Process isolating diaphragm
2Seal
4.7.6 Wall and pipe mounting (optional)
Mounting bracket
Endress+Hauser offers a mounting bracket for installing on pipes or walls (for pipes from 1
1/4
" up to 2" diameter).
In the case of pipe mounting, the nuts on the bracket must be tightened uniformly with a
torque of at least 5 Nm (3.69 lbf ft).
12
A0028493
Maßeinheit mm (in)
122 (4.8)
52 (2.05)
86 (3.39)
70 (2.76)
140 (5.51)
158 (6.22)
175 (6.89)
ø6 (0.24)
ø42...60 (1.65...2.36)