Deltabar FMD71, FMD72
Endress+Hauser 25
Installing the sensor
modules
General installation instructions
Due to the orientation of the sensor modules, there may be a shift in the zero point, i.e. when the
vessel is empty or partially full, the measured value does not display zero.
Always install the sensor module HP below the lowest measuring point.
Always install the sensor module LP above the highest measuring point.
Do not mount the sensor modules in the filling curtain or at a point in the tank which could be
affected by pressure pulses from an agitator.
Do not mount the sensor modules in the suction area of a pump.
The adjustment and functional test can be carried out more easily if you mount the sensor
modules downstream of a shutoff device.
Mounting sensor modules
with PVDF installation
coupling
L
WARNING
Risk of damage to process connection!
Risk of injury!
Sensor modules with PVDF process connections with threaded connection must be installed with
the mounting bracket provided!
The mounting bracket can be installed on pipes with a diameter of 1¼" to 2" or on walls.
A0017514
The mounting bracket is included in the delivery.
Ordering information:
Product Configurator order code for "Enclosed accessories", option "PA" or
as separate accessory (Part No.: 71102216).
Dimensions →  54.
Installing the transmitter
The transmitter is installed with the mounting bracket supplied. The mounting bracket can be
installed on pipes with a diameter of 1¼" to 2" or on walls.
A0021145
The mounting bracket is included in the delivery.
If an additional mounting bracket is required, this can be ordered as follows:
Product Configurator order code for "Enclosed accessories", option "PA" or as separate accessory
(part number: 71102216).
Dimensions →  54.