EasyManua.ls Logo

Endress+Hauser Deltabar FMD72 - Isolating Diaphragm

Endress+Hauser Deltabar FMD72
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deltabar FMD71, FMD72
Endress+Hauser 51
FMD72 process connections,
flush-mounted process
isolating diaphragm
Hygienic connections
A
D1
d
H
d
M
A0021801
B
D1
d
H
d
M
A0021802
C
m
H
d
M
D1
D3
A0021803
D
m
d
M
D1
D3
H
A0021804
Engineering unit mm (in)
Item Description Nominal
pressure
D1 D3
Seal Diaphragm
Height Height Material Weight Option
1)
PN d d
M
H m kg (lbs)
A Clamp
DN18-22
40 34 (1.34) - 27.5
(1.08)
17.2 (0.68) max. 40
(1.57)
- AISI 316L
(1.4435)
0.5 (1.10) TBJ
B Clamp 1" 40 50.5
(1.99)
- 43.5
(1.71)
21.65 (0.85) - 0.6 (1.32) TCJ
Clamp 1½" 40 50.5
(1.99)
- 43.5
(1.71)
28 (1.10) - 0.6 (1.32) TJJ
Clamp 2" 40 64 (2.52) - 56.5
(2.22)
28 (1.10) - 0.7 (1.54) TDJ
C DIN11851 B25 40 43.4
(1.71)
63
(2.48)
- 28 (1.10) 21 (0.83) 0.7 (1.54) MXJ
DIN11851 B32 40 49.4
(1.94)
70
(2.76)
- 28 (1.10) 21 (0.83) 0.8 (1.76) MIJ
D DIN11851 B40 40 55.4
(2.18)
78
(3.07)
- 28 (1.10) 21 (0.83) 0.9 (1.98) MZJ
DIN11851 B50 40 67.4
(2.65)
92
(3.62)
- 28 (1.10) 22 (0.87) 1.1 (2.43) MRJ
1) The roughness of the surface in contact with the medium is R
a
<0.76 µm (30 µin).

Table of Contents

Other manuals for Endress+Hauser Deltabar FMD72

Related product manuals