Deltabar FMD71, FMD72
42 Endress+Hauser
FMD71 process connections,
flush-mounted process
isolating diaphragm
EN/DIN flanges, connection dimensions in accordance with EN 1092-1/DIN 2527
A0026336
Engineering unit mm
Flange Boltholes Weight Option
1)
Nominal diameter Nominal pressure Shape
2)
Material D Thickness Raised face Number g
2
Hole circle
b g k
mm mm mm mm mm kg (lbs)
DN 25 PN 10-40 B1 (D) AISI 316L 115 18 68 4 14 85 1.4 (3.09) CNJ
DN 32 PN 10-40 B1 (D) AISI 316L 140 18 78 4 18 100 2 (4.41) CPJ
DN 40 PN 10-40 B1 (D) AISI 316L 150 18 88 4 18 110 2.4 (5.29) CQJ
DN 40 PN 10-40 B1 (D) ECTFE
3)
150 21 88 4 18 110 2.6 (5.73) CQP
DN 50 PN 10-40 B1 (D) AISI 316L 165 20 102 4 18 125 3.2 (7.06) CXJ
DN 50 PN 10-16 B1 (D) PVDF 165 18 102 4 18 125 2.9 (6.39) CFF
DN 50 PN 25-40 B1 (D) ECTFE
3)
165 20 102 4 18 125 3.2 (7.06) CRP
DN 50 PN 63 (64) B2 (D) AISI 316L 180 26 102 4 22 135 4.6 (10.14) PDJ
DN 80 PN 10-16 B1 (D) PVDF 200 21.4 138 8 18 160 1 (2.21) CGF
DN 80 PN 10-40 B1 (D) AISI 316L 200 24 138 8 18 160 5.5 (12.13) CZJ
DN 80 PN 25-40 B1 (D) ECTFE
3)
200 24 138 8 18 160 5.5 (12.13) CSP
1) Product Configurator order code for "Process connection"
2) Name as per DIN 2527 provided in brackets
3) ECTFE coating on AISI 316L (1.4404). When using in hazardous areas: avoid electrostatic charge on the plastic surfaces.