EasyManua.ls Logo

Endress+Hauser Deltabar FMD72 - Materials in Contact with Process

Endress+Hauser Deltabar FMD72
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Deltabar FMD71, FMD72
Endress+Hauser 55
Materials in contact with
process
NOTICE
Device components in contact with the process are listed in the "Mechanical construction"
→  30 and "Ordering information" sections.
TSE Certificate of Suitability
The following applies to all device components in contact with the process:
They do not contain any materials derived from animals.
No additives or operating materials derived from animals are used in production or processing.
Process connections
Endress+Hauser supplies DIN/EN flanges and threaded connection in stainless steel as per AISI
316L (DIN/ EN material number 1.4404 or 1.4435). With regard to their stability-temperature
property, the materials 1.4404 and 1.4435 are grouped together under 13E0 in EN 1092-1: 2001
Tab. 18. The chemical composition of the two materials can be identical.
"Clamp connections" and "Hygienic process connections": AISI 316L (DIN/EN material number
1.4435)
Some process connections are also available in Alloy C276 (DIN/EN material number 2.4819). For
this purpose see the information in the "Mechanical construction" section.
Process isolating diaphragm
Sensor Description Option
1)
FMD71 Al
2
O
3
aluminum oxide ceramic FDA
2)
, Ceraphire
®
(see also www.endress.com/ceraphire) -
FMD72 AISI 316L (DIN/EN material number 1.4435) A
FMD72 AlloyC (on request) B
1) Product Configurator order code for "Process connection"
2) The US Food & Drug Administration (FDA) has no objections to the use of ceramics made from aluminum
oxide as a surface material in contact with foodstuffs. This declaration is based on supporting documents
from the FDA furnished by our ceramic suppliers.
Filling oil
Description Option
1)
Silicone oil 1
Inert oil (on request) 2
Synthetic oil, FDA 3
1) Product Configurator order code for "Process connection"

Table of Contents

Other manuals for Endress+Hauser Deltabar FMD72