Operating menu and parameter description iTEMP TMT71/72
Device revision
Navigation System Information HART info Device revision
Description Displays the device revision with which the device is registered with the HART
®
FieldComm
Group. It is needed to assign the appropriate device description file (DD) to the device.
User interface Revision in hexadecimal format
Factory setting 0x01
HART revision
Navigation System Information HART info HART revision
Description Displays the HART revision of the device.
HART descriptor
Navigation System Information HART info HART descriptor
Description Use this function to define a description for the measuring point.
User entry Up to 16 alphanumeric characters (upper case letters, numbers and diverse special
characters)
Factory setting 16 x '?'
HART message
Navigation System Information HART info HART message
Description Use this function to define a HART message which is sent via the HART protocol when
requested by the master.
User entry Up to 32 alphanumeric characters (upper case letters, numbers and diverse special
characters)
Factory setting 32 x '?'