• Align the antenna so that it is perpendicular to the product surface.
Optionally, an adjustable flange seal (accessory) can be used for alignment
• A marking is provided on the gland to aid the alignment. This marking must be aligned towards
the tank wall as much as possible.
A0019434
Depending on the device version the marking may be a circle or two parallel lines.
Information concerning nozzles
A0016868
20 Nozzle diameter and height for horn antennas with slip-on flange
ØD Maximum nozzle height H
max
80 mm (3 in) 300 mm (11.8 in)
100 mm (4 in) 400 mm (15.8 in)
150 mm (6 in) 500 mm (19.7 in)