Proline Promag H 300
6 Endress+Hauser
Measuring system
The device consists of a transmitter and a sensor.
The device is available as a compact version:
The transmitter and sensor form a mechanical unit.
Transmitter
Promag 300
A0026708
Device versions and materials:
Transmitter housing
Aluminum, coated: aluminum, AlSi10Mg, coated
Material of window in transmitter housing:
Aluminum, coated: glass
Configuration:
External operation via 4-line, backlit, graphic local display with touch
control and guided menus ("Make-it-run" wizards) for application-
specific commissioning.
Via service interface or WLAN interface:
Operating tools (e.g. FieldCare, DeviceCare)
Web server (access via Web browser, e.g. Microsoft Internet
Explorer, Microsoft Edge)
Sensor
Promag H Nominal diameter range: DN 2 to 150 (1/12 to 6")
Materials:
Sensor housing: stainless steel, 1.4301 (304)
Measuring tubes: stainless steel, 1.4301 (304)
Liner: PFA
Electrodes: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS
N06022); tantalum; platinum (only up to DN 25 (1"))
Process connections: stainless steel, 1.4404 (F316L); PVDF; PVC
adhesive sleeve
Seals:
DN 2 to 25 (1/12 to 1"): O-ring seal (EPDM, FKM, Kalrez), aseptic
molded seal (EPDM, FKM, silicone)
DN 40 to 150 (1 ½ to 6"): aseptic molded seal (EPDM, FKM, silicone)
Grounding rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602
(UNS N06022); tantalum
A0028964
A0028965