EasyManua.ls Logo

Endress+Hauser Proline Promag H 300 - Power consumption; Current consumption; Power supply failure; Electrical connection

Endress+Hauser Proline Promag H 300
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promag H 300
26 Endress+Hauser
Power consumption Transmitter
Max. 10 W (active power)
Current consumption Transmitter
Max. 400 mA (24 V)
Max. 200 mA (110 V, 50/60 Hz; 230 V, 50/60 Hz)
Power supply failure
Totalizers stop at the last value measured.
Configuration is retained in the plug-in memory (HistoROM DAT).
Error messages (incl. total operated hours) are stored.
Electrical connection Connecting the transmitter
Terminal assignment→  24
Device plugs available→  25
1
2
3
A0026781
1 Cable entry for supply voltage
2 Cable entry for input/output signal transmission
3 Cable entry for input/output signal transmission; Optional: connection of external WLAN antenna,
connection of remote display and operating module DKX001 or service plug
Connection of remote display and operating module DKX001
A0027518
1 Remote display and operating module DKX001
2 Connecting cable
3 Measuring device
Remote display and operating module DKX001 →  91

Table of Contents

Other manuals for Endress+Hauser Proline Promag H 300