Proline Promag H 300
Endress+Hauser 73
Coupling ISO 2853, threaded adapter
1.4404 (316L)
Order code for "Process connection", option ICS
DN
[in]
Suitable for pipe EN 10357 (DIN 11850)
[in]
DN
Clamp ISO 2853
[in]
A
[in]
B
[in]
L
[in]
1 ½ 1.50 × 0.06 1.50 Tr 2.00 × 0.13 1.40 10.8
2 2.00 × 0.06 2.01 Tr 2.52 × 0.13 1.91 10.8
3 3.00 × 0.06 3.00 Tr 3.58 × 0.13 2.87 10.9
4 2.50 × 0.08 4.00 Tr 4.65 × 0.13 3.84 11.3
Surface roughness: R
a
≤ 31.5 µin, optional ≤ 15 µin
Please note the internal diameters of the measuring tube and process connection (B) when cleaning with pigs.
Coupling SMS 1145, threaded adapter
1.4404 (316L)
Order code for "Process connection", option SAS
DN
[in]
Suitable for pipe ODT
[in]
DN
SMS 1145
[in]
A
[in]
B
[in]
L
[in]
1 1 1 Rd1.57 × 0.17 0.89 5.81
1 ½ 1.50 × 0.06 1.50 Rd 2.36 × 1/6 1.37 10.1
2 2.00 × 0.06 2.00 Rd 2.76 × 1/6 1.87 10.1
3 3.00 × 0.06 3.00 Rd 3.86 × 1/6 2.86 10.9
4 4.00 × 0.08 4.00 Rd 5.20 × 1/6 3.83 11.3
Surface roughness: R
a
≤ 31.5 µin, optional ≤ 15 µin
Please note the internal diameters of the measuring tube and process connection (B) when cleaning with pigs.
Threaded adapter with O-ring seal
L
A
B
A0027509
External thread according to ISO 228/DIN 2999
1.4404 (316L)
Order code for "Process connection", option I2S
DN
[in]
Suitable for internal thread ISO 228 / DIN 2999
[in]
A
[in]
B
[in]
L
[in]
¹⁄₁₂ to ³⁄₈ R 3/8 Rd 0.40 × 3/8 0.39 6.53
½ R ½ Rd 0.52 × ½ 0.63 6.53
1 R 1 Rd 0.66 × 1 0.98 6.69
Surface roughness: R
a
≤ 63 µin